Morphy Richards
Humidity / Steam Sensor Error (on sensor-cook models)
Display shows H0 or 'Ho' and the microwave does not heat; fan may run briefly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Contaminated humidity sensor, Failed humidity sensor, Loose sensor connector, Faulty sensor circuit on control PCB
How to Fix / Troubleshooting
Safety: Unplug the microwave before accessing internal sensors.
Steps:
- 1. Clean cavity: Wipe down the interior, especially near the top where the humidity sensor port is usually located. Remove grease and food splatter that can coat the sensor.
- 2. Ventilate: Leave the door open for 30 minutes to allow moisture to evaporate, then test again.
- 3. Locate sensor: On sensor-cook Morphy Richards models, the humidity sensor is typically behind a small grille at the top of the cavity. With the unit unplugged and cover removed, access the sensor module.
- 4. Check connections: Ensure the sensor plug is firmly seated on the control PCB and that the wires are intact.
- 5. Replace sensor: If H0 persists, replace the humidity sensor module with a compatible Morphy Richards part.
If replacing the sensor does not clear H0, the control PCB sensor circuit may be defective.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Humidity Sensor
Check Price on Amazon
We may earn a commission from links on this page.