Morphy Richards
Stuck Lamp Circuit / Door Switch Fault
Microwave interior light stays on even when the door is closed and no cooking is in progress.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or misadjusted door switch, Shorted lamp relay on control PCB, Incorrect wiring after previous repair
How to Fix / Troubleshooting
Steps:
- 1. Power reset: Unplug the microwave for 5 minutes, then reconnect. If the lamp still stays on, a hardware fault is likely.
- 2. Check door closure: Ensure the door closes fully and latches. If pressing on the door turns the light off, the door switch alignment is off.
- 3. Inspect door switches (for trained persons): Adjust or replace the door switch assembly so that the lamp circuit opens when the door is closed.
If the switches are correct but the lamp remains on, the control PCB lamp relay may be welded closed and require board replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Door Interlock Switch Kit
Check Price on Amazon
We may earn a commission from links on this page.