Neff No Power – Control Circuit Dead

Microwave display is blank or dead; unit does not respond at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse, Faulty mains filter, Open thermal fuse on cavity or magnetron, Failed control PCB power supply

How to Fix / Troubleshooting

Safety: Unplug the appliance before opening.

Basic checks:

  • Confirm the wall outlet has power and the plug is fully inserted.

Internal checks (qualified):

  • Remove the cabinet and locate the main fuse on the input side. Test and replace with the exact rating if blown.
  • Check thermal fuses on the cavity and magnetron for continuity.
  • Inspect the mains filter and wiring for damage.
  • If fuses and thermal devices are intact, the control PCB power supply may have failed and the board should be replaced.

If a replacement fuse blows immediately, there is likely a short circuit that must be diagnosed before further use.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Internal Main Fuse
Check Price on Amazon

We may earn a commission from links on this page.