Start Circuit / Door Interlock Logic Fault
Microwave display works but pressing START does nothing; timer does not count down.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty door interlock switch, Misaligned door latch, Defective START button on keypad, Control PCB input failure
How to Fix / Troubleshooting
Safety first: Disconnect power before removing the control panel or cabinet.
- Step 1 – Door check: Open and close the door firmly. Listen for distinct clicks from the interlock switches. If the door feels loose or does not latch, inspect the latch hooks for damage.
- Step 2 – Test other buttons: Try setting the clock or using other functions. If only START is unresponsive, the keypad membrane may be worn at that position.
- Step 3 – Child lock: Verify that the child lock is not active (consult your OBH Nordica manual for the specific key combination to toggle it).
- Step 4 – Inspect door switches: With the cover removed and power off, test each door switch with a multimeter for proper continuity when the door is closed. Replace any switch that does not change state reliably.
- Step 5 – Keypad / PCB: If door switches are good, the fault may be in the keypad or control board. Replace the touch control panel assembly first; if the issue persists, replace the main PCB.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Door Switch Assembly or Touch Control Panel