OBH Nordica Worn Keypad Membrane

Microwave keypad buttons are unresponsive or require very hard presses.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Aged touch membrane, Cracked flexible circuit, Moisture ingress behind keypad, Damaged ribbon cable

How to Fix / Troubleshooting

Safety first: Disconnect power before working on the control panel.

  • Step 1 – Test multiple keys: Note which keys fail. If entire rows or columns are dead, the membrane or ribbon cable is likely damaged.
  • Step 2 – Check for child lock: Ensure the control lock feature is not enabled (see OBH Nordica manual).
  • Step 3 – Inspect ribbon cable: Remove the control panel and inspect the flat cable from the keypad to the PCB for cracks or corrosion. Reseat it.
  • Step 4 – Replace keypad: If individual keys remain unresponsive, replace the keypad membrane or the complete control panel assembly with an OBH Nordica-compatible part.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Keypad Membrane / Control Panel
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements