Microwave is completely dead; no display, no light, no response when buttons are pressed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal line fuse, Tripped household circuit breaker, Failed power cord, Defective noise filter board

How to Fix / Troubleshooting

Safety first: Unplug the microwave before any inspection. Never bypass fuses.

Step-by-step checks:

  • 1. Check outlet and breaker: Test the outlet with another device and reset the breaker or replace the fuse in your home panel if tripped.
  • 2. Inspect power cord: Look for visible damage, cuts, or burn marks on the Paderno microwave cord and plug.
  • 3. Access internal fuse: If comfortable, remove the outer cover and locate the main line fuse near the power entry or noise filter board.
  • 4. Test and replace fuse: Use a multimeter to check continuity. If blown, replace only with the exact same rating. If it blows again immediately, stop and call a technician.
  • 5. Inspect noise filter board: Look for burn marks or cracked components on the small board where the power cord connects.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Line Fuse
Check Price on Amazon