Russell Hobbs Start Circuit / Control Logic Fault

Display is on but microwave will not start when pressing Start button

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty Start button on keypad,Door not detected as closed,Child lock enabled,Control PCB relay failure

How to Fix / Troubleshooting

Safety first: Unplug before opening the control panel.

  • 1. Check child lock: Many Russell Hobbs microwaves have a child lock. Look for a lock icon on the display. To clear, typically press and hold the Stop/Cancel or a specific key combination for several seconds (refer to the user manual).
  • 2. Confirm door closure: Ensure the door is fully closed and latched. If the display shows a door error icon, address the door switches first.
  • 3. Test other keys: If other keys respond but Start does not, the Start pad on the membrane keypad may be faulty.
  • 4. Internal inspection (advanced): Remove the control panel and check the keypad ribbon cable and control PCB for damage. Replace the membrane keypad if the Start key is unresponsive.
  • 5. If Start is detected but no relay click: The main power relay on the control PCB may have failed and will need professional replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Membrane Keypad Panel
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements