E-12
Samsung Humidity Sensor Circuit Fault

Microwave displays 'E-12' and auto-cook or sensor cook functions fail to start or stop prematurely.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted humidity sensor, Damaged sensor harness, Faulty control board sensor input, Corroded sensor connector

How to Fix / Troubleshooting

Safety: Disconnect power before inspection. Do not operate the microwave with covers removed.

  • Reset: Unplug for 10 minutes and reconnect. Try a non-sensor manual cook mode. If E-12 appears even in manual mode, hardware is likely at fault.
  • Visual inspection: Check the interior sensor cover for damage or heavy residue. Clean gently with a soft cloth and mild soap, then dry.
  • Check harness (advanced): Remove the control panel and trace the small harness from the humidity sensor to the main PCB. Ensure connectors are fully seated and wires are not pinched or broken.
  • Replace sensor: If wiring looks intact, replace the humidity sensor assembly. If the error persists, the main PCB sensor circuit may need replacement by a professional.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Humidity Sensor Assembly
Check Price on Amazon