Microwave door does not close properly or sags, causing intermittent operation.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Unplug the microwave. A misaligned door can compromise safety interlocks.
Steps:
- 1. Visual inspection: Check if the door is level and flush with the cabinet when closed. Look for gaps or rubbing.
- 2. Tighten hinges: If accessible, tighten any loose hinge screws.
Advanced: If the door or cabinet is bent, or hinges are worn, a technician should replace the door assembly or hinge components with Sharp-approved parts and verify interlock alignment.
Repair Difficulty
Required Part