Siemens
Door Alignment or Latch Failure
Microwave door does not close properly or pops open during operation.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Worn or bent door hinges, weakened door springs, damaged latch hooks, misaligned cabinet frame
How to Fix / Troubleshooting
Safety warning: A door that does not close securely can leak microwave energy. Do not operate the microwave until the door closes and latches correctly.
Steps to try:
- 1. Inspect hinges: Check for visible sagging or misalignment of the door relative to the cabinet.
- 2. Clean seals and frame: Wipe the door gasket area and frame to remove grease that may prevent full closure.
- 3. Check for obstructions: Ensure no utensils or large dishes are pressing against the door from inside.
- 4. Gentle adjustment: On some built-in Siemens models, hinge screws accessible from the front can be slightly tightened to reduce play. Do not overtighten.
- 5. Technician-level: Replace worn hinges or latch components and verify door seal integrity with appropriate tests.
Do not tape the door shut or bypass safety interlocks.