E16
SMEG
Cooling Fan Control Fault
Microwave displays E16; fan may run continuously even when idle.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck cooling fan relay, Shorted triac driving fan, Faulty temperature sensor causing fan overrun, Control PCB logic error
How to Fix / Troubleshooting
Safety: Unplug the microwave before inspection.
User checks:
- Allow the microwave to cool for at least 30 minutes, then plug back in and see if the fan stops after a short period.
- Ensure vents are not blocked, which can cause prolonged fan operation.
Reset:
- Perform a full power reset (unplug 10 minutes, then reconnect).
Technician checks:
- Test the cooling fan motor for correct operation.
- Inspect the control PCB fan relay or triac for welded contacts or shorts.
- Verify temperature sensor readings to ensure the board is not falsely detecting overheat.
Persistent E16 usually requires control PCB or sensor replacement.