E10
Summit Door Sensing Circuit Error

Microwave shows E10 and the interior light does not turn on when the door is opened

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty door switch, Misaligned door latch, Broken door switch actuator, Control board input failure

How to Fix / Troubleshooting

Safety: Unplug the microwave before inspecting door components.

Checks:

  • Open and close the door slowly and listen for distinct clicks from the door switches. A missing click can indicate a failed or misaligned switch.
  • Inspect the door latch hooks for cracks or wear.
  • Check that the door closes evenly and fully against the front frame.

Technical steps:

  • Access the door switch bracket by removing the control panel and inner trim.
  • Test each door switch with a multimeter for proper open/closed operation as the door moves.
  • Replace any defective switch or damaged latch bracket.
  • If switches and latch are good, the control board door input circuit may be faulty and require board replacement.

After repair, verify that the interior light comes on with the door open and that the unit starts only when the door is fully closed.