Summit Door Interlock Safety Failure

Microwave runs with door open or starts when closing the door without pressing START

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Misadjusted or shorted door switches, Broken door latch bracket, Incorrectly installed door, Shorted control board input

How to Fix / Troubleshooting

Critical Safety Warning: A microwave that runs with the door open is dangerous. Unplug it immediately and do not use until repaired.

Steps (for technicians):

  • Inspect and test all door interlock switches for proper operation and correct wiring.
  • Check the door latch bracket and actuators for damage or misalignment.
  • Replace any defective switches and ensure they are installed per Summit's wiring diagram.
  • If switches and latch are correct, the control board may be misreading inputs and must be replaced.

This repair should be performed only by qualified personnel due to radiation safety requirements.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Door Interlock Switch Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements