E14
Telefunken Door Sensing / Monitor Switch Fault

Microwave displays E14 and the interior light remains off even when the door is open; unit may not start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed door monitor switch, Misadjusted door latch assembly, Broken door hinge causing misalignment, Damaged door switch bracket

How to Fix / Troubleshooting

Safety first: Unplug the microwave.

  • Check door alignment: Open and close the door slowly. Ensure it sits evenly and latches smoothly. If the door sags or rubs, inspect hinges and screws; tighten or replace as needed.
  • Inspect door switch bracket: Remove the cabinet and locate the door switch assembly. Ensure the bracket is not cracked or bent, which can prevent proper switch actuation.
  • Test monitor switch: With a multimeter, test the monitor switch according to its NO/NC configuration. Replace if it does not change state correctly when the door is opened/closed.
  • Verify light circuit: If the door switches are good, check the interior light bulb and its socket. Replace the bulb with the correct Telefunken type if blown.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Door Monitor Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements