Telefunken
Door Interlock Safety Failure
Microwave runs with the door open or starts when the door is being closed.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrectly installed door switches, Shorted door monitor switch, Bent door switch bracket, Tampered safety circuit
How to Fix / Troubleshooting
Danger: This is a serious safety hazard. Unplug the microwave immediately and do not use it until repaired.
- Do not attempt to bypass safety switches: Never tape or jumper door switches to keep the unit running.
- Inspect door switch assembly: For trained persons, remove the cabinet and verify that the switches are correctly oriented and firmly mounted.
- Replace faulty switches and bracket: Any damaged switches or bent brackets must be replaced with Telefunken-compatible parts.
- Professional verification: After repair, have a qualified technician verify proper operation and leakage levels.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Door Interlock Switch Set
Check Price on Amazon