Tristar Reduced Heating Power – Weak Magnetron or Low Line Voltage

Microwave interior light, fan, and turntable run, but food heats very slowly compared to normal.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Aging or weak magnetron, Low household line voltage, Failing high-voltage capacitor, Partial short in high-voltage diode

How to Fix / Troubleshooting

Safety: High-voltage diagnosis should be left to professionals.

User-level checks:

  • 1. Compare heating: Heat 1 cup of water for 2 minutes. If it is only lukewarm, heating power is reduced.
  • 2. Check line voltage: Avoid using long extension cords or sharing the circuit with heavy appliances. If possible, have an electrician verify that the outlet voltage is within normal range.
  • 3. Professional service: A technician can test the magnetron output and high-voltage components. Often, replacing the magnetron and capacitor restores full power.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Magnetron
Check Price on Amazon

We may earn a commission from links on this page.