Whirlpool
Door Interlock Switch Miswiring or Failure
Microwave interior light, fan, and turntable come on when door is opened, or continue running with door open
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or welded door switch contacts, Misadjusted door switch bracket, Incorrect switch replacement or wiring, Shorted control board input
How to Fix / Troubleshooting
Safety: This is a serious safety issue. Unplug the microwave immediately and do not use it until repaired.
- Inspect door switches: Remove the control panel and inner trim to access the door switch assembly. Check that each switch is correctly mounted and actuated by the door latch.
- Verify wiring: Compare the wiring to the Whirlpool wiring diagram (usually behind the grille or in the service manual). Ensure each wire is on the correct terminal.
- Replace faulty switches: Any switch that shows continuity when it should be open (or vice versa) must be replaced with the exact Whirlpool part number.
- Control board check: If switches and wiring are correct but the problem persists, the control board may be interpreting signals incorrectly and require replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Door Switch Assembly
Check Price on Amazon