Ambiano
Low Temperature / Underheating
Food is consistently undercooked even when using recommended times and settings.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Weak heating element, Miscalibrated temperature sensor, Faulty pressure sensor reading low, Heat loss due to damaged sealing ring
How to Fix / Troubleshooting
Safety: Unplug and cool the unit before internal checks.
- Verify sealing: Ensure the silicone sealing ring is in good condition and the lid locks properly. Poor sealing reduces effective cooking temperature.
- Check pressure build: Confirm that the float valve rises and the unit reaches full pressure (no continuous venting). If not, address pressure leaks first.
- Test heating: Add 2 cups of water and run a high-pressure or high-heat program. Time how long it takes to reach a vigorous boil. Excessive time may indicate a weak element.
- Inspect element and sensors: From the base, test the heating element resistance and inspect the bottom NTC sensor. Replace any components that are out of specification.
- Adjust recipes: Until repairs are made, increase cooking times slightly, but do not exceed safe fill levels.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Main Heating Element, Silicone Sealing Ring, Bottom NTC Temperature Sensor, Pressure Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements