E14
Daewoo
Keep-Warm Temperature Control Error
E14 displayed; cooker may not maintain correct temperature in keep-warm mode
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Drifted NTC sensor calibration, Faulty keep-warm control circuit on PCB, Poor contact between pot and heater plate, Firmware control error
How to Fix / Troubleshooting
Safety first: Unplug before internal inspection.
- Check pot and plate contact: Ensure the inner pot bottom is clean and flat. Clean the heater plate surface and center sensor area.
- Reset cooker: Perform a factory reset if available (refer to Daewoo manual). This can clear some control logic errors.
- Test with water: Add water and run a cook cycle followed by keep-warm. Use a kitchen thermometer to verify if the temperature is roughly stable.
- Inspect NTC sensor: From the bottom, verify the NTC sensor is firmly attached to the heater plate and wiring is intact.
If E14 persists and temperatures are clearly incorrect, the NTC sensor or main PCB keep-warm circuit likely needs replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
NTC Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements