Possible Causes

Drifted NTC sensor calibration, Faulty keep-warm control circuit on PCB, Poor contact between pot and heater plate, Firmware control error

How to Fix / Troubleshooting

Safety first: Unplug before internal inspection.

  • Check pot and plate contact: Ensure the inner pot bottom is clean and flat. Clean the heater plate surface and center sensor area.
  • Reset cooker: Perform a factory reset if available (refer to Daewoo manual). This can clear some control logic errors.
  • Test with water: Add water and run a cook cycle followed by keep-warm. Use a kitchen thermometer to verify if the temperature is roughly stable.
  • Inspect NTC sensor: From the bottom, verify the NTC sensor is firmly attached to the heater plate and wiring is intact.

If E14 persists and temperatures are clearly incorrect, the NTC sensor or main PCB keep-warm circuit likely needs replacement.