CLOSE
Gourmia Steam Release Valve Not in Sealing Position

Display flashes "CLOSE" and beeps when trying to start; cooker will not proceed.

Advertisements

Possible Causes

Steam release knob set to Vent instead of Seal, Misaligned steam release cap, Worn or missing sealing ring on valve, Valve stem not seated properly

How to Fix / Troubleshooting

Safety first: Ensure the cooker is not under pressure when adjusting the steam release valve.

  • Set valve to Seal: Rotate or flip the steam release knob to the Seal position as indicated on the lid markings.
  • Check valve seating: Remove the valve cap and verify that the stem is correctly inserted and can move freely. Reinstall firmly.
  • Inspect valve gasket: Look for a small silicone ring or gasket on the valve. Replace if cracked, hardened, or missing.
  • Clean valve channel: Clear any food residue from the valve channel that might prevent full seating.
  • Replace valve assembly: If the valve cannot be set to a stable Seal position, install a new Gourmia steam release valve assembly.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

Steam Release Valve Assembly
Check Price on Amazon