E12
Lagostina Display Module / LCD Driver Fault

E12 error appears and the display may flicker or go blank intermittently.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose display connector, Damaged LCD module, Faulty display driver IC on control board, Moisture or condensation behind display window

How to Fix / Troubleshooting

Safety first: Unplug the unit before removing the control panel.

  • Dry the display area: If condensation is visible under the display window, leave the cooker unplugged in a dry, warm room for 24 hours.
  • Inspect display connector: Remove the control panel cover and locate the small connector or ribbon cable going to the LCD/LED display. Reseat it carefully.
  • Check for cracks: Examine the display glass or plastic for cracks or impact damage. A cracked module must be replaced.
  • Test operation: Reassemble and power on. If E12 persists and the display remains unstable, the display module or driver circuitry is defective.

Replacing the display often requires replacing the entire control panel or main board assembly, depending on model design.