E5
Midea
Abnormal Low Pressure / Lid Not Sealed
E5 error appears when trying to start a pressure program; cooker may not build pressure.
Advertisements
Possible Causes
Steam release valve set to vent instead of seal, Damaged or misfitted silicone sealing ring, Debris on lid sealing surface preventing pressure buildup
How to Fix / Troubleshooting
Safety first: Unplug the cooker and ensure it is cool enough to handle.
- Check steam release valve: Verify the valve handle is in the Seal position according to the Midea model markings. Clean the valve cap and ensure it moves freely.
- Inspect sealing ring: Remove the inner lid and silicone sealing ring. Wash with warm soapy water, rinse, and dry. Check for cracks, stretching, or hardening. Reinstall firmly in the groove.
- Clean lid and rim: Wipe the stainless steel rim of the cooker body and the lid contact surface to remove food residue or starch that can prevent sealing.
- Test again: Add water to the minimum line, close the lid, set to Seal, and run a pressure program. If E5 still appears, the pressure sensor calibration or lid locking mechanism may be faulty.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Silicone Sealing Ring
Check Price on Amazon
We may earn a commission from links on this page.