E05
Ninja Internal Temperature Sensor Error

Ninja multicooker shows E05 and will not start or continue a program.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted thermistor on heating plate, Damaged sensor wiring harness, Corroded connector on control board, Failed ADC circuit on main PCB

How to Fix / Troubleshooting

Safety first: Disconnect power before any inspection. Internal sensor testing requires electrical knowledge.

  • Power reset: Unplug the unit for 10–15 minutes to allow the control board to fully discharge, then plug back in and test.
  • Visual inspection: Remove the inner pot and inspect the center of the heating plate area for a visible sensor probe or thermistor mount. Check for physical damage, burnt marks, or loose parts.
  • Check for moisture: If the unit was recently washed or exposed to heavy steam, allow it to dry for 24 hours and retry.
  • Advanced testing: A technician can remove the bottom cover and measure the thermistor resistance at room temperature and when gently warmed to confirm operation.
  • If E05 persists: The temperature sensor or main control board will likely need replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Thermistor / Temperature Probe
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements