E13
Ninja Abnormal Pressure Release / Venting Error

Ninja multicooker shows E13 and stops during pressure release or cool-down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Steam release valve blocked, Anti-clog cap obstructed, Pressure sensor reading inconsistent during venting, Debris in exhaust path

How to Fix / Troubleshooting

Safety first: Keep hands and face away from the steam vent. Allow the unit to fully depressurize and cool before disassembly.

  • Verify full pressure release: Ensure the float valve has dropped and no steam is escaping before opening the lid.
  • Clean vent path: Remove the steam release valve cap and anti-clog cap. Soak them in warm soapy water, scrub gently, rinse, and dry completely.
  • Inspect vent hole: Check the metal vent hole in the lid for starch or food buildup. Clear gently with a non-metallic tool.
  • Run a water test: After reassembly, run a short pressure cycle with water only and observe the release. If E13 recurs, the pressure sensor or control logic may be malfunctioning.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Steam Release Valve Assembly
Check Price on Amazon