E5
OBH Nordica
Pressure Sensor Fault / Pressure Not Detected
E5 error appears when trying to start a pressure program; cooker does not build pressure.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked pressure sensor port, Faulty pressure sensor on lid or body, Loose pressure sensor hose, Damaged wiring to pressure sensor
How to Fix / Troubleshooting
Safety first: Ensure the cooker is unplugged and fully depressurized before working on the lid or pressure components.
- Clean pressure sensor port: On many OBH Nordica multicookers, the pressure sensor is connected to a small metal port or channel near the steam release valve. Remove the inner lid and carefully clean any food residue from the port using a toothpick or soft brush. Do not enlarge the hole.
- Inspect silicone hose (if present): Some models use a short silicone tube between the lid and the pressure sensor. Check that it is not cracked, blocked, or disconnected. Replace if hardened or damaged.
- Check sensor connector: Remove the top or bottom cover (depending on model) to access the pressure sensor module. Ensure the multi-pin connector is firmly seated on the sensor and the main PCB.
- Test with water only: Reassemble, add at least 500 ml of water, and run a pressure program. Listen for the unit attempting to heat and seal. If E5 returns without pressure build-up, the pressure sensor module may need replacement.
Warning: Never block or modify the pressure relief paths; this can create an explosion hazard.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Pressure Sensor Module