E3
Panasonic
Overheat / Dry-Boil Detection (alternate code set)
E3 appears during heating and the cooker shuts off.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Insufficient water, Burnt residue on heater, Faulty temperature sensor, Poor pot contact
How to Fix / Troubleshooting
Safety first: Unplug and let the cooker cool.
- Verify recipe and water: Ensure you are using enough liquid for the selected program.
- Clean pot and heater: Remove burnt food from the inner pot and wipe the heater plate.
- Check pot flatness: Replace the inner pot if the base is warped.
- Sensor check: If E3 recurs, test and replace the heater plate NTC sensor if faulty.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Heater plate NTC temperature sensor