Steba
Keypad / Membrane Switch Failure
Buttons on the control panel do not respond or require very hard pressing; some keys work, others do not.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Worn membrane contacts, Moisture ingress into control panel, Cracked control PCB traces, Contamination under button overlay
How to Fix / Troubleshooting
Safety first: Unplug the cooker before removing the control panel.
Steps to restore button function:
- 1. Clean panel surface: Wipe the keypad area with a slightly damp cloth and mild detergent. Do not allow liquid to seep into the panel.
- 2. Dry thoroughly: If moisture is suspected, leave the cooker in a warm, dry place for 24 hours and retest.
- 3. Access control panel: Remove the front bezel or top cover to expose the control panel PCB and keypad membrane.
- 4. Inspect ribbon and PCB: Check the ribbon cable between the keypad and PCB for damage. Reseat connectors.
- 5. Replace keypad or panel: If individual keys remain unresponsive, replace the keypad membrane or the entire control panel PCB, depending on how Steba supplies spares.
Do not use sharp objects to press buttons; this accelerates wear.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Keypad Membrane / Control Panel PCB
Check Price on Amazon
We may earn a commission from links on this page.