C4
Thermomix Overtemperature Protection Triggered

C4 error appears and the Thermomix stops heating; motor functions may still work.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked ventilation causing internal overheating, Fan failure inside base, Excessive load or thick mixture causing prolonged high current draw, Faulty overtemperature sensor or thermal fuse near heater

How to Fix / Troubleshooting

Safety first: Turn off and unplug the Thermomix. Allow it to cool for at least 30–45 minutes.

  • Improve ventilation: Ensure the unit is on a hard, flat surface with at least 10 cm clearance around sides and rear. Do not operate it under low cabinets where heat accumulates.
  • Reduce load: Avoid overfilling the bowl or using very high temperatures with thick mixtures for extended periods. Follow the maximum fill and speed guidelines in the manual.
  • Check for fan noise: During operation, listen for the internal cooling fan. If you do not hear it or it sounds rough, the fan may be failing.
  • Advanced inspection: With the unit unplugged and bottom cover removed, inspect the cooling fan for obstruction (dust, food particles) and spin it gently by hand. Clean with compressed air and ensure the fan connector is firmly seated.
  • Service requirement: If the fan does not run when powered or the error recurs quickly, the fan or thermal protection circuit must be replaced by a technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Internal Cooling Fan
Check Price on Amazon