E3
Xiaomi Overtemperature Protection Triggered (Base Sensor Overheat)

Multicooker displays E3 and stops heating, often during high-temperature modes like Fry or Sauté.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Overheated heater plate due to empty or low-content pot, Poor contact between inner pot and heater plate, Faulty thermal cutoff or NTC misreading high temperature

How to Fix / Troubleshooting

Safety first: Unplug the cooker and allow it to cool for at least 30 minutes before further inspection.

  • Check cooking conditions: Ensure you are not running high-heat modes with an empty pot or with very little oil/food. Always follow Xiaomi’s minimum content guidelines.
  • Inspect inner pot: Remove the pot and check for warping, dents, or carbon buildup on the bottom. A deformed pot can cause hot spots and poor contact with the heater plate.
  • Clean heater plate: Wipe the heater plate and central sensor area with a soft, dry cloth. Remove any burnt food or residue that could insulate the sensor.
  • Check for blocked ventilation: Ensure the cooker is used on a hard, flat surface with adequate space around it. Do not block side or bottom vents.
  • Reset and test: After cooling, plug the unit back in and test with a low-temperature program (e.g., Rice or Porridge). If E3 appears immediately, there may be a sensor or control fault.
  • Internal inspection (advanced): With the unit unplugged, remove the bottom cover. Inspect the thermal cutoff and NTC sensor on the heater plate for discoloration or damage. Check wiring for signs of overheating.
  • Replace damaged parts: If the thermal cutoff is open or the NTC sensor reads out of range, replace the faulty component with an original Xiaomi-compatible part.
  • Seek service: If E3 persists after verifying pot, cleaning, and sensor condition, the main control board may be misreading temperature and should be checked by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Heater Plate Assembly with Thermal Cutoff and NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements