E4
Xiaomi
Lid Temperature Sensor Fault
Multicooker shows E4 and refuses to start or aborts cooking shortly after start.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted lid NTC sensor, Broken flex cable or wiring in the lid hinge, Loose lid sensor connector on control board
How to Fix / Troubleshooting
Safety first: Disconnect power before inspecting the lid or hinge area.
- Check lid closure: Ensure the lid is fully closed and latched. Some Xiaomi models will show E4 if the lid sensor is not properly engaged.
- Inspect lid sensor area: Open the lid and locate the small metal or plastic sensor near the steam vent or inner lid. Check for physical damage, corrosion, or moisture.
- Dry moisture: If you see condensation or water around the lid sensor, dry it gently with a soft cloth and leave the lid open for several hours before testing again.
- Check hinge wiring: On models with a wired lid, inspect the hinge area for pinched or broken wires. Gently move the lid while looking for exposed conductors.
- Internal connector check (advanced): With the unit unplugged, remove the top or side cover (depending on model) to access the lid sensor connector on the PCB. Reseat the connector and inspect for bent pins.
- Resistance test: If accessible, measure the lid NTC sensor resistance at room temperature and compare to the base sensor’s approximate value. A reading of 0 Ω or infinite resistance indicates a failed sensor.
- Replace lid sensor: If the sensor is defective or its cable is damaged, replace the lid temperature sensor or lid harness with a Xiaomi-compatible part.
- Professional help: If wiring and sensor appear intact but E4 persists, the control board’s sensor input may be faulty and should be diagnosed by a service center.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Lid NTC Temperature Sensor / Lid Wiring Harness
Check Price on Amazon
We may earn a commission from links on this page.