F15
AEG Water Level / Overflow Sensor Fault

F15 error, oven may show water-related warning and disable steam functions.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective water level sensor in steam generator, blocked level tube, wiring fault to level sensor, control board misinterpretation

How to Fix / Troubleshooting

Safety first: Disconnect power and allow the oven to cool.

  • Inspect level sensor: Locate the water level sensor on or near the steam generator. It may be a float switch or conductivity probe. Clean any scale or residue.
  • Clear level tube: If a small tube connects the boiler to the sensor, ensure it is not blocked with limescale. Carefully flush with descaling solution if necessary.
  • Check wiring: Verify that the sensor wiring harness is intact and firmly connected to the control board.
  • Replace sensor: If the sensor does not change state when water level changes (test per service manual), replace it with the correct AEG part.

Warning: Do not bypass level sensors; this can cause dangerous overfilling or dry-boil conditions.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Steam Generator Water Level Sensor
Check Price on Amazon