Oven displays F9E0 and will not operate; may appear after installation or power outage.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: This involves live 240V circuits. If you are not experienced with electrical work, contact a licensed electrician or appliance technician. Always turn off the breaker before opening the terminal block cover.
Step-by-step checks:
- Verify breaker: Ensure the range is on a dedicated double-pole 240V breaker and both handles are ON.
- Inspect terminal block: Remove the rear terminal block cover. Check that the power cord or conduit is securely attached and that L1, L2, and Neutral are correctly positioned per the wiring diagram on the unit.
- Tighten connections: With power OFF, tighten all terminal screws. Look for signs of arcing or melted insulation; replace damaged parts.
- Measure voltage: With power ON and using a multimeter rated for 240V:
- L1 to L2 should read ~240V.
- L1 to Neutral and L2 to Neutral should each read ~120V.
- Control board: If supply voltage is correct but F9E0 persists, the EOC may be misreading line voltage and should be replaced.
Repair Difficulty
Required Part
We may earn a commission from links on this page.