American Range Keypad Wear or Control Panel Failure

Control panel buttons are unresponsive or require very hard presses to register.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Worn touch membrane, Cracked control overlay, Loose keypad ribbon connection

How to Fix / Troubleshooting

Safety first: Disconnect power before removing the control panel.

  • Check for lock mode: Ensure the control lock feature is not engaged (see LOC instructions).
  • Inspect overlay: Look for cracks, bubbling, or wear on the keypad overlay. Physical damage usually requires replacement.
  • Ribbon cable: Remove the control panel and verify the keypad ribbon is fully seated in the EOC connector. Clean contacts if necessary.
  • Replace keypad: If specific buttons consistently fail, replace the keypad/touch panel assembly with the correct American Range part.

Note: Avoid using sharp objects or excessive force on the keypad to extend its life.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Touchpad / Keypad Assembly
Check Price on Amazon

We may earn a commission from links on this page.