Amica Partial Keypad Failure

Oven display works but some buttons or touch areas do not respond.

Advertisements

Possible Causes

Worn membrane keypad, Damaged touch sensor traces, Faulty button switches, Broken ribbon cable to UI board

How to Fix / Troubleshooting

Safety first: Disconnect power before removing the control fascia.

  • Test all keys: Note which buttons or touch areas fail. If an entire row or column is dead, suspect the ribbon cable or connector.
  • Inspect ribbon cable: Remove the control panel and check the flexible cable for cracks or kinks. Reseat or replace as needed.
  • Membrane or touch panel: If only certain keys fail and the cable is good, replace the membrane keypad or glass touch panel assembly, depending on model.
  • UI PCB: If replacing the panel does not restore function, the user interface PCB may be defective and should be replaced.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Control Panel Keypad / Touch Panel
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements