F10
Bauknecht
Door Switch / Door Contact Fault
Oven shows F10 and does not start, often related to door not being detected as closed.
Advertisements
Possible Causes
Faulty door switch or contact, Misaligned door causing poor switch engagement, Broken switch actuator on door or frame, Wiring fault between switch and control board
How to Fix / Troubleshooting
Safety first: Turn off power before removing any panels or working near live parts.
- Check door closure: Ensure the door closes fully and evenly. Look for bent hinges or warped door that might prevent the switch from engaging.
- Locate door switch: On many Bauknecht ovens, the door switch is located behind the front panel or in the door frame area. Remove the control panel or front trim to access it.
- Actuation test: Manually press the switch plunger and listen for a distinct click. If it feels mushy or sticks, replace the switch.
- Continuity test: Disconnect the switch and test with a multimeter. It should change from open to closed (or vice versa) when pressed. Replace if readings are inconsistent.
- Adjust alignment: If the switch is good, adjust its mounting position so that the door fully depresses it when closed.
- Wiring check: Inspect the wiring from the switch to the control board for breaks or loose connectors.