F40
Bauknecht Mains Voltage / Frequency Error

Oven shows F40, often after a power outage or when supply voltage is unstable.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect mains voltage (too low or too high), Unstable power supply, Internal voltage sensing circuit fault on control board, Neutral or earth connection issue at terminal block

How to Fix / Troubleshooting

Safety first: Switch off power before opening the terminal block cover.

  • Check supply: Have a qualified person measure the mains voltage at the oven connection. Ensure it matches the rating plate (e.g. 230 V, 50 Hz).
  • Inspect terminal block: Remove the rear cover to access the mains terminal block. Check for loose screws, burnt terminals, or melted plastic. Tighten connections and replace damaged blocks.
  • Phase configuration: On multi‑phase models, ensure the jumpers are configured correctly according to the installation diagram.
  • Control board: If supply is correct and connections are sound, the voltage sensing circuit on the control board may be faulty and the board will need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Electronic Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements