F9
Clatronic
Mains Power / Line Voltage Error
F9 displayed, oven may trip the household breaker or not power up correctly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect mains connection, neutral and live reversed or missing, loose terminal block connections, internal short circuit in wiring or components
How to Fix / Troubleshooting
Safety first: This involves mains wiring. If you are not experienced with electrical work, contact a qualified electrician or technician. Always disconnect power at the breaker before opening the terminal block cover.
- Check supply: Verify that the oven is connected to the correct voltage and phase as specified on the Clatronic rating plate.
- Inspect terminal block: Remove the rear terminal cover and inspect the mains connection block. Tighten any loose screws and ensure wires are correctly placed according to the wiring diagram.
- Look for damage: Check for burnt insulation, melted plastic, or signs of arcing. Replace the terminal block if damaged.
- Internal short: If F9 persists and breakers trip, there may be a shorted heating element or wiring. Disconnect elements one by one and test insulation resistance to chassis. Replace any component that shows a short.