Possible Causes

Failed bake or broil relay, Shorted triac controlling elements, Heat damage to control board

How to Fix / Troubleshooting

Safety First: Disconnect power before accessing the control board. High voltages are present on relay contacts.

  • Visual inspection: Remove the control panel and inspect the board for burnt relay contacts, darkened areas, or cracked solder joints near the element relays.
  • Check element operation: If only one function (bake or broil) fails with E5, suspect the corresponding relay. If both fail, the board's power section may be damaged.
  • Replace control board: Danby control boards are not typically repaired at component level. Replace the entire board with the correct part number.
  • Verify cooling: Ensure the control area cooling fan (if equipped) is working to prevent repeat failures.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Electronic Oven Control Board
Check Price on Amazon