Danby Stuck Door Switch or Control Relay

Oven interior light stays on even when the door is closed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Door switch stuck in closed position, Misaligned door not depressing switch, Stuck light relay on control board

How to Fix / Troubleshooting

Safety First: Disconnect power before testing the door switch.

  • Check door alignment: Ensure the door closes fully and presses the switch plunger. Adjust hinges if needed.
  • Test switch: Remove the switch and test with a multimeter. It should change state when pressed. Replace if stuck closed.
  • Control relay: If the switch is good but the light remains on, the control board's light relay may be stuck. Replace the control board.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Oven Door Switch
Check Price on Amazon