Danby
Stuck Door Switch or Control Relay
Oven interior light stays on even when the door is closed.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Door switch stuck in closed position, Misaligned door not depressing switch, Stuck light relay on control board
How to Fix / Troubleshooting
Safety First: Disconnect power before testing the door switch.
- Check door alignment: Ensure the door closes fully and presses the switch plunger. Adjust hinges if needed.
- Test switch: Remove the switch and test with a multimeter. It should change state when pressed. Replace if stuck closed.
- Control relay: If the switch is good but the light remains on, the control board's light relay may be stuck. Replace the control board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Oven Door Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements