F18
Falcon Meat Probe / Temperature Probe Fault

Display shows error related to probe or meat sensor, cooking with probe not possible

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Damaged meat probe, Probe socket failure, Broken wiring to probe connector, Control board probe input fault

How to Fix / Troubleshooting

Safety: Disconnect power before accessing internal wiring.

  • Inspect the probe: Check the Falcon meat probe cable and tip for cuts, kinks, or damage. Replace the probe if damaged.
  • Test probe resistance: At room temperature, measure resistance across the probe plug. Compare with Falcon specifications; if open or shorted, replace the probe.
  • Check probe socket: Inspect the Falcon probe socket inside the oven for corrosion or bent contacts. Replace if necessary.
  • Wiring and PCB: If a known-good probe still triggers an error, the wiring or control board input may be faulty and require professional diagnosis.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Falcon meat probe
Check Price on Amazon