F17
Fisher & Paykel Cooling Fan Control Circuit Stuck On

Oven display shows F17 and the cooling fan runs at high speed continuously, even when the oven is cold and off.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted cooling fan triac on control board, Stuck fan relay contacts, Shorted wiring causing constant fan supply, Control board logic fault

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before accessing the control board.

  • 1. Confirm behaviour: Restore power and observe if the fan starts immediately without any cooking function selected. Turn power off again.
  • 2. Inspect control board: Remove the control panel or top cover to access the main board. Identify the cooling fan relay or triac. Look for signs of overheating or cracking.
  • 3. Wiring check: Ensure the cooling fan is not accidentally wired directly to mains due to a previous repair. Correct any miswiring.
  • 4. Replace control board: If the relay or triac is welded closed or the board is damaged, replace the main control board. Component-level repair is not typically supported.

Running the cooling fan continuously is not dangerous but indicates a control fault that should be corrected to avoid further board damage.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Oven Control Board
Check Price on Amazon

We may earn a commission from links on this page.