E12
Gram Real-Time Clock / Memory Fault

Oven shows E12 and the clock/timer cannot be set or resets randomly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty clock module on control board, Power supply instability to control PCB, Corrupted EEPROM on main PCB, Loose ribbon cable to display board

How to Fix / Troubleshooting

Safety first: Switch off power before accessing the control area.

Steps to check:

  • Remove the control panel fascia to access the display/clock board and its ribbon cable.
  • Reseat the ribbon cable and connectors between the display and main PCB.
  • Inspect the PCB for signs of moisture or corrosion; clean with appropriate electronics cleaner.
  • Verify that the mains supply to the oven is stable and that the terminal block connections are tight.
  • If E12 persists and the clock loses time or settings, replace the control panel module or the main PCB depending on model design (some Gram ovens integrate the clock into the main board).

Warning: Do not spray cleaners directly onto the control panel; liquid ingress can damage electronics.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Control Panel Module
Check Price on Amazon