E16
Hoover Cooling Fan Overrun / Sensor Fault

Hoover oven shows E16 and the fan continues running for an unusually long time or not at all after cooking.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty cavity temperature sensor, Stuck cooling fan relay, Defective main PCB logic, Wiring fault to sensor or fan

How to Fix / Troubleshooting

Safety first: Disconnect the oven from mains power before accessing internal components.

  • Observe behaviour:
    • Note whether the fan never stops, never starts, or behaves erratically.
  • Check temperature sensor:
    • Test the main cavity temperature sensor (NTC) for correct resistance at room temperature.
    • Replace if readings are out of specification.
  • Inspect fan relay:
    • Locate the cooling fan relay on the main PCB.
    • Check for signs of welded contacts (burning, discoloration).
    • If the relay is stuck closed or open, the PCB will need repair or replacement.
  • Check wiring:
    • Verify continuity of wiring between the sensor, fan, and PCB.
    • Repair any damaged harness sections.
  • Final test: Reassemble, restore power, and run a short heating cycle. Confirm that the fan starts and stops appropriately and that E16 is cleared.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board / Cooling Fan Circuit
Check Price on Amazon