E16
Ilve
Temperature Sensor Short-Circuit or Calibration Error
Oven displays E16 and the cavity temperature reading is clearly wrong (e.g., shows 300°C when cold).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted NTC sensor, sensor wire insulation damaged and touching chassis, moisture ingress into sensor, faulty ADC input on main control board
How to Fix / Troubleshooting
Safety first: Disconnect power and allow the oven to cool.
Sensor and wiring checks:
- Remove the temperature sensor from the cavity and inspect the wiring for cuts or crushed insulation.
- Measure resistance at room temperature; a very low resistance (near 0 Ω) indicates a shorted sensor.
- Check for continuity between each sensor lead and the oven chassis; any reading indicates a short to ground.
- Replace the sensor if shorted or contaminated with moisture.
- If the sensor and wiring are good but readings are still incorrect, the main control board's sensor input circuit may be defective and require board replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Main Oven Temperature Sensor (NTC Probe)
Check Price on Amazon
We may earn a commission from links on this page.