E15
Logik
Low Voltage / Power Supply Fault
Logik oven shows E15 and the display is dim, flickering, or resets when heating starts.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose mains terminal block, Failing internal power supply on PCB, Poor neutral connection, Overloaded circuit or undersized cable
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker. Only work on mains connections if you are competent; otherwise, contact a qualified electrician.
- Check supply: Confirm the oven is on a dedicated circuit with the correct rating as specified by Logik. Avoid using extension leads.
- Inspect terminal block: Remove the rear cover to access the mains terminal block. Tighten all live, neutral, and earth screws. Look for heat damage or discoloration; replace the block if burnt.
- Check cable size: Ensure the supply cable is of adequate gauge for the oven’s power rating. Undersized cable can cause voltage drop.
- PCB power supply: If the external supply is sound, the internal low-voltage power supply on the main PCB may be failing. Inspect for bulging capacitors or burnt components. Replace the PCB if defective.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control PCB (Power Supply Section)
Check Price on Amazon