F9E0
Maytag
Line voltage or wiring error
F9E0 error, miswired oven or improper power supply detected
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect L1/L2/neutral connections, missing neutral, reversed polarity, loose terminal block connections
How to Fix / Troubleshooting
Safety First: This involves live 240V circuits. If you are not experienced with electrical work, contact a licensed electrician.
- Turn off breaker: Ensure power is OFF before opening the rear terminal block cover.
- Inspect terminal block: Verify that L1, L2, and neutral are connected according to the wiring diagram on the oven.
- Tighten connections: Check that all terminal screws are tight and wires are not burnt.
- Verify supply voltage: With a multimeter and extreme caution, verify 240V across L1–L2 and ~120V from each leg to neutral.
- Correct wiring: Correct any miswiring per the installation manual. Replace a damaged terminal block if needed.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Power Terminal Block
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements