Midea
Memory / Backup Power Loss
Oven clock and settings reset every time power is cycled or briefly interrupted
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty main control board memory circuit, Internal capacitor failure, Loose power connections causing brief outages, Power supply instability
How to Fix / Troubleshooting
Safety first: Turn off power before accessing internal wiring.
Check power stability:
- Inspect the terminal block and power cord for loose connections.
- Ensure the oven is on a dedicated circuit as recommended by Midea.
Control board:
- If power is stable but settings are lost after every outage, the main control board memory/backup circuit is likely failing.
- Replace the main control board using the correct part number for your model.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements