E17
Morphy Richards
Self-Clean Lock / Temperature Interlock Fault
Morphy Richards oven shows E17 and the self-clean or pyrolytic cycle cannot be started.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Door lock not engaging, Faulty self-clean temperature sensor, Control board not detecting safe conditions, Wiring fault to lock or sensor
How to Fix / Troubleshooting
Safety first: Ensure the oven is cool and disconnected from mains before inspection.
Steps:
- Check door lock: Attempt to start self-clean and listen for the lock motor. If it does not operate, inspect the door lock assembly and wiring.
- Verify door switch: The control must detect a closed door. Test the door switch for correct operation.
- Check self-clean sensor: Some models use a separate high-temperature sensor. Test its resistance and wiring according to the service manual.
- Control logic: If all hardware checks out, the electronic control board may not be recognising conditions and may require replacement.
Warning: Do not attempt to bypass safety interlocks for self-clean; this can cause severe damage or fire.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Door Lock Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements