E016
Neff Low-Voltage Auxiliary Circuit Fault

Neff oven displays E016 and the interior light or auxiliary functions may not work

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed low-voltage transformer on PCB, shorted oven lamp holder, shorted cavity light wiring, damaged auxiliary output on control board

How to Fix / Troubleshooting

Safety first: Disconnect the oven from mains before inspecting internal wiring or the lamp holder.

  • Check oven lamp: Remove the lamp cover and bulb. Inspect for broken glass or shorted filament. Replace with the correct Neff-rated oven bulb.
  • Inspect lamp holder: Look for signs of arcing or burning around the lamp holder and its wiring. Replace if damaged.
  • Test with lamp removed: With the bulb removed and power restored, see if E016 still appears. If the error clears, the bulb or holder was likely the cause.
  • PCB inspection: If E016 persists, remove the control board and inspect the low-voltage section (transformer, rectifier, regulators) for damage.

Replace the lamp and holder if faulty. If the low-voltage supply on the PCB has failed, the main control board will usually need replacement.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Oven Lamp Holder
Check Price on Amazon