F9
OBH Nordica
Mains Frequency / Synchronization Error
Oven displays F9 and may shut down unexpectedly or not start.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Unstable mains frequency, Faulty frequency detection circuit on PCB, Electrical noise from other appliances, Loose neutral or live connection at terminal block
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before accessing the rear of the oven.
Steps to check:
- Inspect terminal block: Remove the rear cover and check that all screws on the mains terminal block are tight. Loose connections can cause erratic frequency readings.
- Check for shared circuits: Avoid running the oven on a circuit heavily loaded with other large appliances that may introduce electrical noise.
- Power reset: After tightening connections, disconnect power for 10 minutes, then restore and see if F9 clears.
- Control board replacement: If the mains supply is stable and connections are secure but F9 persists, the frequency detection circuit on the main PCB is likely faulty. Replace the control board.
Note: If you suspect issues with your home's electrical supply, consult a licensed electrician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board (Oven PCB)
Check Price on Amazon
We may earn a commission from links on this page.